Version 7.0.3 - Released 7/15/2026

  • An issue was resolved that would cause variable references in a restart cases extra deck data to be corrupted when saving the case.
  • An issue that would prevent restart cases with long variable names from functioning correctly has been resolved.
  • An issue that would incorrectly replace variables when graphically editing a restart case if those variables name is a fragment inside another variables name.
  • An issue was resolved that caused the multiplex control block type component selection dialog to display invalid components to allow connections when the create button was used.
  • Updated the new control block types to support all the properties within a restart case.
  • The Radionuclide Signal variable was updated to support exporting the paramter value identifying a volume inside a 3D component.
  • The Signal Variable component has been updated to only display the known types for the current model code flavor.
  • The Radionuclide signal variables have been updated to display the correct RN specie name within the display name of the variable when the connected RN specie name is modified.
  • The Interactive Variables 'Variable Request Code' property has been updated to remove the 'Number' column from the component selection dialog.
  • The Reynolds Junction values Forward B, Forward C, Reverse B, and Reverse C corresponding cards now support a collapsing format. Ticket 58
  • The Label for the Inlet and Outlet Properties on a Hydro Component has been updated to correctly wrap text under the buttons.Ticket 57
  • An issue was resolved that caused the Hydro Component cell Azimuthal Angle and Third Angle properties to not support being set to a numeric variable within the tabular editing dialog.
  • An issue was resolved that allows setting the hydraulic volume components to a rotation matrix cell geometry in RELAP5-3D versions 4.1 and newer.
  • An issue was resolved that caused the Branch component Cell orientation table to display a 'Third Angle' property that is not used within a Branch component.
  • Subsystem importing of Reactor Kinetcs was updated to resolve an issue where Reactivity Contro l component referencs could be lost.
  • The Table Variable Creation Dialog within the Volume Weighting Factors Table now correctly builds the Numeric Table from the dialog.
  • The Heat Weighting Dialog has been updated to show the correct amount of columns when a Table Variable is set on the dialog.
  • The Model Options component was updated to set the model to modified when the Minor Edit Requests property is changed.
  • The Additional Junction Options for a hydraulic component in RELAP53D have been updated to be editable when the Choking Model on the respective junction is set to 0 or 1.

Version 7.0.2 - Released 3/21/2026

  • The RELAP plug-in has been updated to support importing quoted enumeration values.
  • The Friction Critical Speed now supports the default value of 0.0 within the Pump Components Pump Description Attribute group.
  • The Control Block in RELAP now supports the MPLEX Control Block Type.
  • The plug-in was updated to support the INTERPOL and RAMP control block types.
  • A bug was resolved that caused additional components to be added to a new subsystem when importing an existing subsystem from another model that contains the Reactor Kinetics component.

Version 7.0.1 - Released 9/16/2025

  • An issue was resolved that caused the Reactors Kinetics component to fail to be exported when the Heat/Volume Weighting tables included unknown or dollar-variable values.
  • Added a go-to button to custom RELAP editors that support component references.
  • An ASCII Import issue has been resolved that would prevent ASCII import from completing when the restart filename is specified on record 104.
  • An issue was resolved that would prevent identifying unrecognized cards as extra deck data during ASCII import.
  • An issue was resolved that failed to import the Time Dependent Volume CCC0200 record when the data option set to control.
  • The pump control property has been updated to not support selecting general table or interactive variable components
  • The 1-D hydro component Geometry property has been updated to indicate "Invalid Geometry" when the Azimuthal Angle or Third Angle properties are not set.
  • The Multi-Dim component Node Geometry property label has been updated to indicate 'Invalid Values' when the NC Gas values do not sum to one.
  • Ensure that the Head/Torque Curves label indicates when there's an invalid value in the dialog
  • The Head/Torque Curves dialog within Pumps was updated to disable the remove button when no rows are selected.
  • Ensure that the last column in the radial geometry dialog can be set properly according to the model version
  • An editor that supports selecting a numeric variable reference has been updated to use the SNAP-CORE selection dialog.

Version 7.0.0 - Released 7/21/2025

  • The Spray Junction property editing dialog within Pressurizer of Hydraulic Components was updated to hide the “Number” column, which always shows –1.
  • The Inlet Junction property editor of turbines was updated to prevent selecting an inlet junction number less than 1.
  • The Time Dependent Volume initial conditions editing dialog’s remove button has been updated to be disabled when no rows are selected.
  • Resolved minor pasting bug with the Connections dialog within Multiple Junctions of Hydraulic Components
  • Resolved minor bugs with the 1D and 2D Tabular Fraction Limit property dialog editors within Separators of Hydraulic Components
  • An issue was resolved when attempting to set the Compressor Outlet Option property on multiple components. This property does not support setting on multiple components at one time. Now, the combo box is not displayed when multiple compressors are selected in the Navigator.
  • The Wall Friction tab within the Turbine Friction Data property has been updated to remove the axis drop-down and the defaults button because these features do not affect the turbine component.
  • Fixed a typo in the Head Curves editor within pumps when multiple components are selected.
  • The Fission Product Decay property for Reactor Kinetics can now be specified using a SNAP Variable.
  • The Power History table is no longer editable unless the Fission Product Decay flag is nonzero.

Version 6.9.6 - Released 3/21/2025:

  • Scale Factor, Initial Velocity, and Final Velocity in the Displacement Table dialog can now properly reference shared reals.
  • The Managed Connections dialog within the Model Options component has been updated to use the updated Numeric Variable selection dialog when modifying the controlled connections.
  • The integer selection button of the Inlet and Outlet properties in Valves within Hydraulic Components is now always enabled, and the selection dialog has the ability to create new integers.
  • The real selection button of the Initial Value property under the Interactive Variables group within the Control Systems component is now always enabled, and the selection dialog has the ability to create new real values.
  • The Model Options Self Initialization Options Pressure value now allow referencing a SNAP Variable.
  • The Reactor Kinetics Reactor Time property has been updated to allow referencing a SNAP Variable.
  • The Control Option value in the Time Step Control property (found in Times Steps attribute group within Model Options component) now supports selecting and creating a numeric integer.
  • In the Geometry dialog (of Multi-Dim component within Hydraulic Components), when the Display Actual Positions checkbox is selected, the dialog will not allow selecting a numeric variable.
  • The 1D-Hydraulic Components Initial Conditions dialog was updated to use the integer numeric selection dialog that supports creating a new numeric variable for the Velocities or Mass flow type property.
  • An issue was resolved that could prevent opening the Hydro Component Geometry dialog after the model version was modified.
  • The integer selection button of the Initial Position property in Valves within Hydraulic Components is now always enabled, and the selection dialog has the ability to create new integers.
  • An issue was resolved closing the Model Editor after the data within the Radiation Enclosure Heat Structures property was modified.
  • The Multijunction component was updated to resolve an issue which would prevent creating new junction signal variables on a multijun through Python bindings.
  • The Python bindings for Pipe, Annulus, and Prizer were updated to allow setting the Area, Length, Volume (ALV) calculation mode for the entire component, or to set the ALV mode by cell.

Version 6.9.5 - Released 9/25/2024:

  • An issue was resolved in which messages that occur during model import would not appear.
  • An issue was resolved in which no messages would be reported during a graphical edit of a restart case.
  • The graphical display of restart cases has been updated to resolve an issue where Reset Trip records were not resupplied in drawn views correctly.
  • The popup help text for Leak Fraction has been updated to changed based on if the SLAM model is enabled or not.
  • An issue was resolved in which jet mixer components were drawn incorrectly when oriented vertically.

Version 6.9.4 - Released 7/17/2024:

  • The RELAP5-3D plugin was updated to support version 4.5.
  • An issue was resolved that caused opening a restart view that has elements deleted from the base model view to fail to load.
  • An issue was resolved that caused the Control Block Diff/Merge panel to not support merging an unset Trip reference.
  • Undo/redo support was added to the Control Block Diff/Merge panel Trip node.
  • An issue was resolved that caused Control Connections to be removed when loading a legacy model from before RELAP 6.7.3.
  • An issue was resolved that caused the restart plot file type to be required. Now it is possible to import record 103 without the restart file format flag.
  • The RELAP5-3D plugin was updated to support version 4.5.
  • The Reactor Kinetics component Interior Boundary property has been updated to only support values 0 (zero current) and 3 (cyclic) when the Kinetics Type is Nodal and the model is a RELAP5-3D version greater than 4.4.
  • The Restart and Plot Action property in Model Options has been updated to support 'csv' for RELAP5-3D version 4.5 when not editing a restart case.
  • Support was added for the FREETAB format for general tables in RELAP5.
  • Freetab now supports external files being set as the interpolation data.
  • Linear and Polynomial Interpolation are currently the two interpolation types supported within RELAP5.
  • An issue was resolved that caused the Model Editor to lock up when saving a restart case.
  • The heat structure component has been updated to resolve an issue where adding a cell through the Cells dialog would cause errors if the individual value option is selected for surface temperatures.
  • The property editor for real properties with variable units has been updated to support a modification that only removes characters. This includes Variable Initial Value and Variable Trip Additive Constant.